What is an agronomic soil test?

The agronomic P soil test is an index of P availability which means that we can use the soil test to determine likeliness of a response to additional P. An agronomic soil test extracts only a small portion of the total amount of P in the soil as not all of that P is available for crop growth. Agronomic soil test results are classified as low, medium, high or very high based on crop response to additional P; crops grown on soils that are already high or very high in P are not likely to respond with a yield increase if additional P fertilizer is added. On the other hand, soils that are low or medium in P will likely show higher yields if extra P is added. For more information on P fertilizer use for corn, see Agronomy Fact Sheet 8: Starter Phosphorus Fertilizer for Corn.

(Modified) Morgan soil test method

To determine the Cornell Morgan soil test P of a soil, the soil is shaken (extracted) with a chemical solution (sodium acetate buffered at pH 4.8) in a particular soil to extraction solution ratio (1:5) and for a certain amount of time (15 minutes). The extract is filtered (Figure 1) and the P concentration in the filtered extract is measured in the laboratory (colorimetrically). Cornell University is not the only university that uses the Morgan soil test. This same test is the basis for fertility guidelines of the University of Massachusetts and a similar chemical extraction solution (ammonium acetate instead of sodium acetate called the Modified Morgan extraction) is used for fertility guidelines at the Universities of Maine, Vermont, Connecticut, and Rhode Island. The Morgan and Modified Morgan soil tests give similar results as long as the soil to solution ratio, scoop sizes, shaking time, filter paper, and instrumentation used to determine P concentration in the extracts, are identical and samples are corrected for weight and moisture content.

Other soil testing methods

Several other tests were developed for the same purpose: to predict if additional P is needed for optimum economic yields. The most commonly used tests are the Mehlich-3 soil test, the Bray-1 and the Olson P tests. These three tests use a very different chemical extraction solution. The Mehlich-3 extraction solution is an unbuffered solution of acetate, ammonium nitrate, ammonium fluoride, nitric acid, and ethylenediaminetetraacetic acid (EDTA). The Bray-1 solution is an unbuffered dilute HCl and ammonium fluoride solution. The procedures for the Mehlich-3 and Bray-1 extractions call for a 1:10 soil to solution ratio and 5 minutes of shaking time. The Olsen procedure contains sodium bicarbonate and was specifically developed for calcareous soils.

How do soil test results compare?

Different tests will give different results as some of the chemical solutions are much more aggressive in extracting P from the soil than others. The Mehlich-3 solution is the most aggressive and that results in the highest soil test values. The Bray-1 solution usually results in slightly lower values that the Mehlich-3 analyses (usually between 70-85% of the value of the Mehlich-3 test). The Olsen and (Modified) Morgan tests are weaker with the Morgan test extracting the smallest amounts of P. The test results from one method are not always directly comparable to those of another method. Figure 2 shows that depending on the soil, the Mehlich-3 test can extract anywhere between 3 and 30 times as much P as the Morgan test!

Conversion models

If the pH of the soil and the amount of Mehlich-3 extractable P, Ca and Al are known, an estimate of the Morgan soil test P value can be derived. These conversions will not be totally accurate for all soils and require sampling in the fall at a 2-3 sample per acre density for greatest accuracy (see Figure 3).

Laboratory to laboratory differences

Slight differences in laboratory procedures (e.g. different soil to solution ratios, shaking times, filter paper, etc.) will lead to differences in the soil test results. This can be seen in Table 2 for four random soil samples. Thus, laboratory specific conversions need to be used to derive Cornell Morgan soil test estimates from Mehlich-3 data.

A stand-alone excel conversion tool is available from the Nutrient Management Spear Program website: http://nmsp.css.cornell.edu/software/ morganequivalents.asp. When you use this conversion tool, make sure to correctly identify (1) the laboratory that generated the Mehlich- 3 data, and (2) the units (ppm versus lbs/acre)! Input data needed for the conversion from Mehlihc-3 data to Morgan equivalents are: soil pH, Mehlich-3 extractable P, Ca and Al. Keep in mind that not all soils give reliable conversions; always check field histories to make sure the results make sense!

Additional Resources


Also in Blog

Advanced Cooling Tower Management: Enhancing Efficiency with Lakewood Model 140
Advanced Cooling Tower Management: Enhancing Efficiency with Lakewood Model 140

February 28, 2024 0 Comments

View full article →

Optimizing Cooling Tower Performance: Understanding Efficiency, Maintenance, and Water Quality Management
Optimizing Cooling Tower Performance: Understanding Efficiency, Maintenance, and Water Quality Management

February 28, 2024 0 Comments

Implementation of the Lakewood 3175 controller in cooling tower systems, emphasizing its significant role in enhancing operational efficiency, reducing chemical usage, and mitigating issues related to corrosion and deposition. It highlights the controller's ability to automate the management of water conductivity, ensuring optimal water quality and system performance. Examples and hypothetical calculations are provided to illustrate the controller's benefits, including water savings, cost reductions in chemical treatments, and energy efficiency gains through the prevention of scale buildup and corrosion. The Lakewood 3175 controller is presented as a strategic tool for achieving a more sustainable, efficient, and cost-effective cooling tower operation, demonstrating the value of advanced technology in industrial water management.

View full article →

Revolutionizing Water Analysis: Everything You Need to Know About the Kemio KEM10DIS
Revolutionizing Water Analysis: Everything You Need to Know About the Kemio KEM10DIS

April 19, 2023 0 Comments

The Palintest Kemio KEM10DIS is a highly accurate, fast, and easy-to-use water analysis device that offers several advantages over other methods. Its portability and wide measurement range make it ideal for use in a range of applications, from drinking water to industrial process water. With its patented Dual-Field technology and fast results, the Palintest Kemio KEM10DIS can help to improve the efficiency of water treatment processes and reduce the risk of contamination. Compared to other methods, the device is highly accurate and easy to use, making it accessible to a wide range of users. By following the simple procedure outlined above, users can quickly and easily obtain accurate results for a range of parameters, helping to ensure the safety and quality of water for various applications.

View full article →