Kemio™ is the next generation measurement platform, delivering the validation you need from a method you can trust. Kemio™ utilizes a sophisticated electrochemical technique that removes complexity for the user, giving you clear results for confident decision making.
- Repeatable and reliable results with minimal user input
- Automatically stores all results for a complete, auditable dataset
- Truly simple test method requiring no user training
- Get clear pass/fail results to enable corrective action
- Suitable for all sample types, not affected by color, turbidity, floating particles or ambient light
- Kemio uses the same EPA approved method as the ChloroSense and ChlordioX Plus
Multiparameter testing platform
Kemio™ performs tests for Chlorine (free and total), Chlorine Dioxide, Chlorite and Peracetic Acid (PAA) on one instrument with the use of different sensors.
KIT CONTENT
Instrument, soft protective case, check standards, USB cable, international power adapter, quick start instructions and stylus soft case for transporting Kemio and consumables.
REAGENTS
Reagent |
# of Tests |
Range |
Part number |
CR-1 Reagent (Chlorite Test) |
|
|
PT546 |
CR-2 Reagent (Chlorite Test) |
|
|
PT547 |
Glycine Reagent |
|
|
PT549 |
Kemio Sensors for Chlorine (High Range) |
100 |
Free Chlorine 0.1 – 25 mg/LTotal Chlorine 1- 500 mg/L |
KEM21CHR |
Kemio Sensors for Chlorine (High Range) |
500 |
Free Chlorine 0.1 – 25 mg/LTotal Chlorine 1- 500 mg/L |
KEM25CHR |
Kemio Sensors for Chlorine (Standard Range) |
100 |
Free Chlorine 0.02 - 10 mg/LTotal Chlorine 0.02 - 75 mg/L |
KEM21CLO |
Kemio Sensors for Chlorine (Standard Range) |
500 |
Free Chlorine 0.02 - 10 mg/LTotal Chlorine 0.02 - 75 mg/L |
KEM25CLO |
Kemio Sensors for Chlorine Dioxide/Chlorite |
100 |
Chlorine Dioxide 0.02 - 500 mg/LChlorite 0.02 - 50 mg/L |
KEM21CDX |
Kemio Sensors for Chlorine Dioxide/Chlorite |
500 |
Chlorine Dioxide 0.02 - 500 mg/LChlorite 0.02 - 50 mg/L |
KEM25CDX |
Kemio Sensors for Paracetic Acid (Low Range) |
100 |
0.02 – 50 mg/L |
KEM21PAL |
Kemio Sensors for Paracetic Acid (Low Range) |
500 |
0.02 – 50 mg/L |
KEM25PAL |
Kemio Sensors for Paracetic Acid (PAA) |
100 |
5 – 2000 mg/L |
KEM21PAA |
Kemio Sensors for Paracetic Acid (PAA) |
500 |
5 – 2000 mg/L |